Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0624-03323
Parcel: 11106271B

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0624-03323
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/02/2024 Site Engineering APPROVED
08/14/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/23/2024 Residential Building REQUIRES RESUBMIT TC-RES-0624-03323 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with submitting the updated construction plan set.

SECTIONS - DETAILS:

1. Clarify the placement of ceiling/roof insulation for compliance, R806. Both standard and high-density R-30 batt insulation requires a space greater than provided with 2” x 6” framing, N1102.1. Identify the products that provide the intended minimum R-30 total value with air-impermeable rigid insulation material applied correctly to either side of the roof sheathing, R806.5.
2. The sleeping loft requires an egress window in compliance with AQ105.1 and R310. Show minimum net clear opening area of 5.7 SQ FT with “casement” noted at the egress window note on sheet A2.0.

ELECTRICAL PLANS:

1. Kitchen countertop receptacles require 2O AMP circuits, E3703.2 and E3901.3. Update circuit #6 to 20 AMP.
2. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
08/14/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0624-03323
2841 North Palo Verde Avenue – R-2
Convert existing storage room to living quarters (2nd Review)

TRANSMITTAL DATE: August 14, 2024

1. The waiver provided as a separate attachment should be pasted directly onto the site plan and physically signed rather than electronically signed.

If the waiver cannot be obtained, the setback may be reduced through a Design Development Option (DDO). The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Mark.Castro@tucsonaz.gov or Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
07/18/2024 PDSD Application Completeness Express REVIEW COMPLETED