Permit Number: TC-RES-0624-03323
Parcel: 11106271B

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0624-03323
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/01/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/17/2024 Residential Building REQUIRES RESUBMIT TC-RES-0624-03323
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with submitting the updated construction plan set.

SITE PLAN:

Provide a site plan showing utilities for the altered building, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations.

STRUCTURAL PLANS:

1. The proposed living space within the 3’ fire separation distance from the primary dwelling requires compliance with R302.1 (City of Tucson Amended) by providing one-hour rated materials at the roof projection underside in compliance with IBC Table 721.1(2), Items 15-1.1 to 16-1.3, R106.1.

SECTIONS - DETAILS:

1. Provide a structure section showing existing and proposed features including framing, sheathing and insulation, R106.1. Indicate if the insulation is existing or proposed.
2. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38.
3. Show compliance with AQ104.2 for loft access and AQ104.2.5 for loft guards. Also, a sleeping loft requires an egress window in compliance with AQ105.1.

PLUMBING PLANS:

1. Show an accessible water supply shut off valve for the altered building, P2903.9.1.

MECHANICAL PLANS:

1. Show heating/cooling facilities in the sleeping area, R303.9.

ELECTRICAL PLANS:

1. Show the panelboard location with clear working space of 30” wide x 36” deep, E3405.2.
2. Show a smoke alarm location in each room, R314.3.
3. Show a 2O AMP small appliance circuit at the kitchen countertop receptacle outlet, E3703.2 and E3901.3.
4. Show Bathroom receptacle with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6.
5. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16.

OUTDOOR LIGHTING CODE

Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
07/01/2024 Site Engineering REQUIRES RESUBMIT This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home
NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed.
Instructions:
1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2. Locations -> Confirm the location is accurate to the project. Click “Next”
3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”
6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”
7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”
Contact Mike Ortiz at Michael.Ortiz@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP.
06/24/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0624-03323
2841 North Palo Verde Avenue – R-2
Convert existing storage room to living quarters (1st Review)

TRANSMITTAL DATE: June 24, 2024

1. Based on the lot dimensions of 50’ by 120’, the lot size of the property should be listed as 6,000 square feet. Update the lot coverage calculations to reflect the correct lot size.

2. As a refrigerator and freezer are depicted on the floor plan, clarify whether the proposal is considered a sleeping quarters or a dwelling unit. Per a previous Zoning Administrator’s determination dated May 29, 1996, for the proposal to not be considered a residential unit, the project is limited to having a refrigerator that can fit below a sink counter, a wet bar sink, and no cooking facilities. Further comments will be forthcoming if a dwelling unit is proposed.

3. Clarify the existing use of the site. The property appears to currently be developed with a duplex. If a third dwelling unit is proposed, a separate development package that meets the requirements of Administrative Manual Section 2-06 is required for a change of use to multifamily development.

The separate development package is required to be submitted, reviewed, and approved by all reviewers prior to zoning approval of TC-RES-0623-03323. A development package is not required for the proposal if the refrigerator and freezer are removed from the floor plan.

4. Per a previous Zoning Administrator’s determination dated December 21, 2005, a permitted detached accessory structure, such as the existing storage room, that does not meet setback requirements and is proposed to be converted to habitable space requires the consent of the adjoining property owner. A neighbor’s setback waiver in accordance with UDC 6.6.2.D can be used to reduce the setback as measured from the west lot line. The waiver shall be signed by the owner of 3438 East Monte Vista Drive and shall also be pasted on the site plan with the following language:

My name is _______ and I am the owner of property located at _______. I have reviewed the site plan and have no objection to the structure being located __ feet from the property line as depicted on the site plan.

Signature: _______

Date: _______

If a dwelling unit is proposed, the setback may only be reduced through a Design Development Option (DDO). The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Mark.Castro@tucsonaz.gov or Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
06/03/2024 PDSD Application Completeness Express REVIEW COMPLETED