Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0623-06243
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2023 | Site Engineering | NOT REQUIRED | |||
| 07/19/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/19/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-06243 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. Each dwelling requires an independent electrical service and water supply shut off devices. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Notate a cool (white) roof finish as required by the ADU provisions. 2. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1. SECTIONS - DETAILS: 1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation or need for providing air-impermeable rigid insulation at the roof, R806. Show an unvented roof assembly with all insulation at the roof including an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total insulation requirement, R806.5 or show the attic vent opening size using 1 to 150 of attic area with insulation at the ceiling in compliance with R806.2. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate water meter location at the property edge. Show an appropriate 1” supply pipe to a branch line point where the size may be reduced to ¾”. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. Notate if the mechanical plans if system calculations will be provided by deferred submittal. ELECTRICAL PLANS: 1. Update the Riser Diagram showing a service disconnect for each dwelling without service disruption of the other dwelling, NEC 225.30 and E3403. 2. Notate smoke detectors with arc-fault circuit protection, E3902.16. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 07/10/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0623-06243 402 S. Fremont Av. – R-2 New Accessory Dwelling Unit (ADU) (1st Review) TRANSMITTAL DATE: May 12, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) with an accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. 1. The property dimensions are not correct. Per Manlove Amended plat lot 14, block 5 the dimensions are 50’ x 160’. 2. The lot coverage calculation is not correct. The lot size used 4,247 S.F. is not correct, based on a 50’ x 160’ lot the lot size should be 8,000 S.F.. Per UDC Article 6.4.3.C.1.a, Roofed areas, porches, open on at least one side and not included. Also per UDC Article 6.4.3.B.3.b any vehicle use area, whether improved or unimproved, is included. 3. The Front Setback listed under Zoning Info: is not correct. Per UDC Article 6.4.5.C.1.a the setback should be 20’-0”. 4. The side setback shown on the plot plan for the property line along Manlove St is not correct. Per UDC Article 6.4.5.C.1.b the setback should be 10’-0”. 5. Per UDC Article 6.6.3.B.4 an ADU may not exceed 12’ in height. Building Height is the vertical distance measured from the design grade elevation to the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof. See UDC Article 6.4.4.A & Figure 6.4.4-A. Provide a dimension of the elevations from design grade to the midpoint of the pitched room so that building heights can be verified. 6. Clearly demonstrate that the requirements of UDC Article 6.6.3.B.2 and .3 are met for the proposed ADU. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As wall height dimensions were not provided from design grade to the highest point of the wall Zoning has used the 13’-11” dimension provided from finished floor to the peak of the roof. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on the wall height of 13’-11” the required perimeter yard setback to the west property line is 9.3’ proposed setback is 7.5’. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 06/30/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 07/06/2023 | Site Landscape | REVIEW COMPLETED |