Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0623-06217
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2023 | Site Engineering | NOT REQUIRED | |||
| 07/19/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/19/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-06217 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. PLANS: 1. Notate a cool (white) roof finish as required by the ADU provisions. SECTIONS - DETAILS: 1. Show an unvented roof assembly with all insulation at the roof including an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing as part of the total insulation requirement, R806.5. PLUMBING PLANS: 1. Show the appropriate clothes washer graywater detail provided at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation for clarifying discharge from the building. 2. Gray water systems may only receive waste discharge from bathtubs, showers, lavatories, clothes washers and laundry trays, P2601.2 & Table P3009.9. Remove the gray drain lines from the food preparation sinks. 3. Provide devices rated for application, G2406.3. A diverter valve for waste drainage requires a manufacturer approved listing. Provide documentation or remove the device from the bathroom drain line. 4. Show each gas pipe segment sized in conformance with Table G2413.4(1). Show the required pipe size between the meter and first branch tee for the total developed length. MECHANICAL PLANS: 1. Update the code reference at note #1. 2. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1. 3. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the system and appropriate flow rate setting on the plans. A two or three bedroom dwelling under 1501 SF requires a 45 CFM continuous setting. 4. Show combustion air compliance for appliances in confined spaces, G2407.5. ELECTRICAL PLANS: 1. Clothes Washer and Dishwasher GFCI: receptacles require readily accessible protection typically from an upstream device, E3902.9 & 10. Add notation to the panel schedule. 2. Show all circuits requiring arc-fault circuit interrupters on the panel schedule, E3902.16. Include circuit #13. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 07/12/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Nathan Herrera Planner PROJECT: TC-RES-0623-06217 Address: 7902 S Farmbelt Dr. Tucson, AZ. 85756 Parcel: 140-44-2120 Zoning: SH Existing Use: Single Family Residence Project Description: Accessory Dwelling Unit (ADU) TRANSMITTAL DATE: 7/12/2023 This site is located in the SH zone (UDC 4.7.5). A single-family residence is a permitted use in this zone (Table 4.8-1). 1. COMMENT: Per City of Tucson Unified Development Code (UDC) Section 6.6.3.B.3, “If the accessory dwelling unit is built as a new structure it must be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code.” Demonstrate on the plan-set how the above requirement is being met for the proposed ADU. 2. COMMENT: Per UDC Section 6.6.3.C, “Detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line.” Per the site plan, the porch of the proposed ADU is in the buildable area between the principal building and front street lot line. The ADU will need to be moved north so the porch is behind the front wall of the principal building. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or 520-837-4894. |
||
| 06/30/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |