Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0623-06172
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/03/2023 | Site Engineering | NOT REQUIRED | |||
| 07/13/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/13/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-06172 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Identify these items as built without permit. Show the as-built addition with necessary alterations for achieving code compliance. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: Provide a site plan showing dimensions of all buildings requiring a permit, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. FLOOR PLAN: Provide a floor plan showing each proposed room with labeled function and dimensions. Show door locations and window sizes with type identified as XO or SH. Include the identification of adjacent rooms with door or window openings in the proposed space. All bedrooms require an emergency egress to the exterior. STRUCTURAL PLANS: 1. Provide complete structural plans showing compliance with the IRC, R301.1. Show all roof framing with 2018 IRC compliance, R301.1. SECTIONS - DETAILS: 1. Provide a structure section showing existing and proposed features including a foundation, sills, anchoring, framing, sheathing and insulation, R106.1. 2. Show a complete cross-section detail of the new exterior wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show with dimensions the exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. PLUMBING PLANS: 1. Provide complete plumbing plans showing any changes with 2018 IRC compliance, R301.1. MECHANICAL PLANS: 1. Show heating facilities in all habitable rooms, R303.9. ELECTRICAL PLANS: 1. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. 2. Show the location of the sub panel. Sub panels shall not be located in clothes closets or bathrooms, E3405.5 3. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 07/06/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-RES-0623-06172 5943 E BEVERLY ST Zoning R-1 TRANSMITTAL DATE:July 6, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf This shall in include: a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements. (Lot coverage must include vehicular use area whether improved or unimproved) . Lot coverage does not include porches, UDC Article 6.4.3.C.1.a but does include vehicle use area measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved. b. Zoning of adjacent parcels c. All Utility lines d. Property line distances 2.COMMENT: Provide an elevation drawing. 3.COMMENT: Clearly show everything on site. Based on current aerial photos there is a possible unpermitted structure on the north east portion of the site. Additional comments may be forth coming. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 06/30/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |