Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0623-06163
Parcel: 141411640

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0623-06163
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/29/2023 Site Zoning APPROVED
07/03/2023 Site Engineering NOT REQUIRED
07/14/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
07/14/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0623-06163 (6724 E VIA ARROYO LARGO TUCSON, AZ 85756)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), International Swimming Pool and Spa Code (ISPSC), National Electrical Code (NEC).

1. Note and specify all piping materials and sizes, P2609.
2. Provide a #18 yellow tracer wire with nonmetallic piping, G2415.14.3.
3. Provide electrical circuit requirements of the pool equipment. Show conductors sized for the given requirements. E3705.4.1.
5. Notate burial depth, tracer lines and type of material used for all utility lines to the pool equipment and from the equipment to the pool.
6. Bond the perimeter surface and reinforcing steel as required by ISPSC 302.1 and NEC 680.26(B)(2).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
06/29/2023 PDSD Application Completeness REVIEW COMPLETED