Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0623-06137
Parcel: 119223310

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0623-06137
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2023 Residential Building APPROVED
06/28/2023 Site Engineering NOT REQUIRED
07/17/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/05/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0623-06137
2011 W. Tourney Rd. - R-1
Detached Garage (1st Review)

TRANSMITTAL DATE: July 05, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9, & .11

1. Provide fully dimensioned elevations with the next submittal. Per UDC Article 6.6.3.D the maximum height of a detached accessory structure is 12’-0”. This measurement is from design grade to the midpoint of the pitched roof, UDC Article 6.4.4.A & Figure 6.4.4-A. If this structure exceeds the allowed 12’ a Board of Adjustment for Variance will be required. A Board of Adjustment for Variance must be submitted and approved. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/pdsd/zoning-administration-applications. If you have questions about the Board of Adjustment application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

2. Remove the perimeter yard setback lines along the south and east property line as they are not correct. Until comment #1 is addressed Zoning cannot determine setback requirements. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
06/28/2023 PDSD Application Completeness Express REVIEW COMPLETED