Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0623-06114
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2023 | Site Engineering | NOT REQUIRED | |||
| 07/13/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/13/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-06114 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. SITE PLAN: Show the location of all utility lines from property line to building(s) along with required alterations, R106.1.1. STRUCTURAL PLANS: 1. Provide an engineer’s calculation, design and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. 2. A special inspection request is required with the permit application for field welding, R109.2. 3. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2). If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 07/05/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0623-06114 – CE-VIO-0423-03092 2941 E. 24th St. - R-1 Carport Addition (1st Review) TRANSMITTAL DATE: July 05, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9, & .11 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This plot plan shall show all structures on site. 2. It is not clear if the carport is attached or detached to the main dwelling. If attached clearly show the connection, if detached a Board of Adjustment for Variance will be required, UDC Article 6.6.3.C. If attached provide the street permit yard setback from the post supporting the carport to the street property line. Additional comments maybe forth coming once the above comments are addressed. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/28/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |