Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0623-06014
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/12/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-06014 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions and concerns before permit approval. FLOOR PLANS: 1. Show the functional name of the adjacent room to the proposed garage, R106.1.1. An opening from a garage directly into a sleeping room is not permitted, R302.5.1. 2. Show the door from a garage to dwelling with a 20-minute fire rating (or 1-3/8” solid core) with self-closing and self-latching provision, R302.5.1. STRUCTURAL PLANS: 1. Show braced wall panel compliance for (narrow) framed walls with a garage door opening, Table R602.10.5. For prescriptive braced wall structures show a portal frame with hold-downs PFH method, Figure R602.10.6.2, or a portal frame at garage door PFG method, Figure R602.10.6.3, or a continuously sheathed portal frame CS-PF method, Figure R602.10.6.4. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 07/05/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0623-06014 2917 East Hardy Place – R-1 Garage addition (1st Review) TRANSMITTAL DATE: July 5, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9. 1. Provide a lot coverage calculation in accordance with UDC 6.4.3.C. Lot coverage includes the area of the lot covered by buildings, outdoor storage areas, and vehicular use areas, whether improved or unimproved. Ensure lot coverage does not exceed 70% (UDC Table 6.3-2.A). 2. Show all structures on the site plan. A shade sail attached to the principal structure appears in Google Street View and aerial photography beginning in 2022. Zoning was unable to determine whether a permit was obtained for this structure. If necessary, include the shade structure in this permit’s scope of work, or indicate whether this specific shade sail will be removed. The required side street perimeter yard setback is 10’-00” as measured from the east property line. Some sort of administrative process such as a DDO or a variance will be required to allow this shade structure to remain with a reduced setback. 3. The following comment is relative to an application for a Board of Adjustment variance (UDC 3.10.3). Per UDC 6.4.5.C.1.b, “where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line.” However, “for carports and garages which face the street, the minimum required street perimeter yard is 20 feet regardless of the street.” A Board of Adjustment variance is required to be granted to allow the setback from the east lot line to the proposed garage to be reduced to 10’-00”. A Design Development Option (DDO) may be utilized if the garage is proposed as a carport, or if the garage may maintain a distance of at least 18’-00” as measured from the east lot line. Contact Mark.Castro@tucsonaz.gov should you have questions regarding the variance process. Additionally, contact Georgia.Pennington@tucsonaz.gov should you have questions regarding the DDO process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 06/23/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 06/26/2023 | Site Engineering | REVIEW COMPLETED |