Permit Number: TC-RES-0623-05954
Parcel: 130170380

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0623-05954
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/24/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/07/2023 Residential Building REQUIRES RESUBMIT TC-RES-0623-05954
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

SITE PLAN:

Provide a site plan showing dimensions of all buildings requiring a permit, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Update detail A/A-6.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show a minimum 1” yard pipe size.
2. Show the branch drain size as required by P3201.7. The minimum water closet pipe diameter is 3” rather than 2”.

ELECTRICAL PLANS:

1. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
09/21/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-RES-0623-05954 - CE-VIO0323-02470
426 N. Kent Dr. - R-1
Expand Master Bed & Bath & Add Patio (2nd Review)

TRANSMITTAL: September 21, 2023

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. This comment was not addressed. The setback listed along Montezuma Ave. is not correct and should be 20’-0”.

2. This comment was not addressed. The setback listed along 27th St. is not correct and should be 10’-0”.

3. This comment was not addressed. The Existing Portable Storage shown along 27th St. shows up on aerial photos sometime after 2020. Zoning was not able to find an approved permit or compliance review for this structure and it does not meet the minimum 10’-0” setback. As this structure appears to be at a 0’-0” street setback a Board of Adjustment for Variance is required for this structure to remain as shown on the plan.

A Board of Adjustment for Variance must be submitted and approved. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/pdsd/zoning-administration-applications. If you have questions about the Board of Adjustment application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
08/24/2023 PDSD Application Completeness Express REVIEW COMPLETED
08/29/2023 Site Engineering REVIEW COMPLETED