Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0623-05946
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/10/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0623-05946 (6462 E CALLE LUNA TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide consistent information and calculations, R106.1. 2. Sheet PV 1 shows 16 existing Enphase IQA-72-2-US inverters while sheets PV5 and PV 6 show 16 existing Enphase IQ8Plus-72-2-US inverters. Update plans with correct and consistent inverter mode #, R106.1. 3. Sheets PV 5 and PV 6 show 16 existing P320 Optimizers, which have a max power rating of 320 W, while the Existing Tesla T420S modules have a max power rating of 420 W. The output short-circuit current and open-circuit voltage of the Tesla models exceed the max limit of the P320 Optimizers. The P320 Optimizers are not rated to support the Tesla models. Verify and correct this on the plans. 4. The Wire Size Calculations and OCPD calculations on Sheet PV 5 and PV6 are incorrect and don’t match the spec sheet data. Correct the calculations to match the provided spec sheets, R106.1, R324. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |