Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.2
Permit Number - TC-RES-0623-05946
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/16/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0623-05946 (6462 E CALLE LUNA TUCSON, AZ 85710) 2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). The written response letter needs to list all of the numerated points below and address each of them. 1. You need to use the correct existing inverters and solar modules in the plans and calculations. a. The correct Existing micro inverter: IQ7-60-2-US. b. The correct Existing Tesla modules: T420S. c. There are NO Optimizers in the approved plans for the existing system. d. See Pima County permit Record P21BP09326. 2. Your AC wire calculations need to use the correct information from the correct spec sheets. All of these comments were unaddressed. 3. Provide consistent information and calculations, R106.1. 4. Sheet PV 1 shows 16 existing Enphase IQA-72-2-US inverters while sheets PV5 and PV 6 show 16 existing Enphase IQ8Plus-72-2-US inverters. Update plans with correct and consistent inverter mode #, R106.1. 5. Sheets PV 5 and PV 6 show 16 existing P320 Optimizers, (or are you adding Optimizers?), which have a max power rating of 320 W, while the Existing Tesla T420S modules have a max power rating of 420 W. The output short-circuit current and open-circuit voltage of the Tesla models exceed the max limit of the P320 Optimizers. The P320 Optimizers are not rated to support the Tesla models. Verify and correct this on the plans. 6. The Wire Size Calculations and OCPD calculations on Sheet PV 5 and PV6 are incorrect and don’t match the spec sheet data. Correct the calculations to match the provided spec sheets, R106.1, R324. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/15/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |