Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0623-05909
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/16/2023 | Site Engineering | NOT REQUIRED | |||
| 07/07/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/07/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0623-05909 (2634 E MALVERN ST TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Use Table E3705.1, 60 degree C column, for sizing branch circuits and conductors rated at 100 AMP or less, E3705.4.1. 2. Show the sub-panel bus rating, feeder conductor size and over-current protection (breaker size), E3705.5. 3. Provide an #18 yellow tracer wire with nonmetallic piping, G2415.14.3. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/15/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 06/22/2023 | Site Zoning | REVIEW COMPLETED | zoning stamp not required |