| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/05/2023 | Residential Building | NOT REQUIRED | Wall/Fence 7' or under. | ||
| 06/15/2023 | Site Engineering | NOT REQUIRED | |||
| 06/14/2023 | Site Landscape | NOT REQUIRED | |||
| 07/05/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/21/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0623-05862 3001 E. 4th St. - R-1 Extend Site Wall Height (1st Review) TRANSMITTAL: June 21, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. The carport shown in the northeast corner of the site shows up on aerial photos sometime after 2008. Zoning was not able to find approved Zoning compliance review documents for this carport. Based on the square footage shown on the plan this structure does not require a building permit but is required to meet perimeter yard setbacks to the north and east property lines of 6’-0” or 2/3 the height of the exterior wall, greater of the two, as measured from the post supporting the structure. and the height restriction of UDC Article 6.6.3.D accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height. Show the perimeter yard setbacks and provide the height of this structure on the plan so that setback requirements can be verified. If the structure does not meet perimeter yard setback per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 2. Show the curb along both 4th and Bentley and provide a dimension from the centerline of both streets to the face of curb, where pavement meets the curb, and from face of curb to the property line. 4th St. distance from centerline to curb is 19.6’ and face of curb to property line is 20.0’, Bentley distance from centerline to curb is 18.0’ and face of curb to property line is 12.0’. 3. Remove the setback references from the plan as they are not correct. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 06/14/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |