Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.6
Permit Number - TC-RES-0623-05852
Review Name: RESIDENTIAL NEW DWELLING v.6
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/16/2023 | Residential Building | REQUIRES RESUBMIT | After DDO approval submit a complete construction plan set for 2018 IRC compliance review. 1. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide not less than one-hour fire-resistive construction on the underside. This may be 5/8" Type X gypsum board fastened tot he underside of rafter (overhang) ends near the property line. |
||
| 11/14/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0623-05852 - CE-VIO0323-02470 426 N. Kent Dr. - R-1 Carport Addition (4th Review) TRANSMITTAL: November 14, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. On the next submittal please provide a complete plan set. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 9’-0” the required perimeter yard setback from the proposed carport structure to the north property line is 6’-0”, the proposed setback is 2’-0”. A Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf . The completed application shall be submitted as a PDF under assigned permit number . If you have questions about the DDO application or process please contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at georgia.pennington@tucsonaz.gov If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 11/16/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | DDO-23-87 is currently in progress. If the DDO is approved, provide a copy of your DDO decision letter in addition to a revised plan set and comment response letter under existing permit number TC-RES-0623-05852. Contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 should you have questions about the DDO process. |
||
| 11/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |