| 07/05/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/05/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-05852 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: Provide a site plan showing dimensions of all buildings requiring a permit, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. STRUCTURAL PLANS: 1. Provide complete structural plans showing compliance with the IRC, R301.1. Show all proposed structure with 2018 IRC compliance, R301.1. 2. Show the location of each support footing, R106.1.1. 3. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. SECTIONS - DETAILS: 1. Show a complete cross-section detail of support columns, R106.1.1. Show the footing size with #4 rebar reinforced and fasteners, R403.1. 2. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 06/28/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Please provide a north arrow that indicates which direction the front of the building faces. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 06/21/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0623-05852 - CE-VIO0323-02470 426 N. Kent Dr. - R-1 Carport Addition (1st Review) TRANSMITTAL: June 21, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 06/14/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |