Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0623-05852
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/14/2023 | Site Engineering | NOT REQUIRED | |||
| 08/22/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/22/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-05852 R1 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Consider using a design professional if unfamiliar with construction documentation. Combine each page of the construction plans into a single file. Place sheet numbers on each sheet of construction plans. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: Provide a site plan showing dimensions of all buildings requiring a permit, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. STRUCTURAL PLANS: 1. Provide complete structural plans showing compliance with the 2018 IRC, R301.1. 2. Provide a Roof Framing Plan showing the location and size of posts, beams, and rafters for supporting live and dead structural loads, R804. 3. Provide complete structural (roof framing) plans showing compliance with the IRC or provide an Arizona structural engineer plan set showing performance compliance, R301.1. SECTIONS - DETAILS: 1. Show a complete cross-section detail of support columns, R106.1.1. Show the footing size with #4 rebar reinforced and fasteners, R403.1. 2. The proposed Carport may be sited within the 3’ fire separation distance from a property line. Show compliance with R302.1 (City of Tucson Amended) by providing a wall with one-hour rated materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3, R106.1 or remove any structure closer than 3 feet to the property line. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 08/16/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-RES-0623-05852 - CE-VIO0323-02470 426 N. Kent Dr. - R-1 Carport Addition (2nd Review) TRANSMITTAL: August 16, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. This comment was not fully addressed. Review the requirements and provide all the required information to include but not limited to the below comments. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. a. The plot plan shall be drawing at an engineering scale, i.e. 1” = 10’ , 1” =20’. b. Provide the owners name. c. Provide a lot coverage calculation on the plot plan that meets the requirements of Unified Development Code (UDC) Article 6.4.3 and the example shown on the Residential Plot Plan Requirements. d. Show the locations of all utility lines. e. Provide a dimension from the center line of Kent Dr. to the face of curb, where pavement meets the concrete, and from face of curb to the street property line. The distance from center line to face of curb is 16’ and from face of curb to the property line is 9’. f. Provide perimeter yard setback dimensions from the carport to the street property line and to the north property line. Per UDC Article 6.4.5.B.2 for carport structures the setback is measured from the post supporting the structure to the property as long as the roof overhang does not exceed 2’-0”, UDC Article 6.4.5.D.1 & .2. g. Provide the height of the exterior walls of the carport, Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. For carport type structures this measurement is from design grade to the top of the beam supporting the roof. h. Provide the legal description, “CARRIAGE HILL LOT 0023”. 2. Per UDC Article 6.4.5.C.1 the street perimeter yard setback is 20’-0”. 3. Per UDC Table 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 Zone, the perimeter yard setback is 6’-0” or 2/3 (H) = Height of the proposed exterior building wall, the greater of the two dimensions applies, as measured as mentioned above. If the minimum setback is not met for either the street or north property line a Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact, Zone1.desk@tucsonaz.gov |
||
| 08/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |