Permit Number: TC-RES-0623-05826
Parcel: 133361070

Address:
9712 E 5TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0623-05826
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2023 Site Engineering NOT REQUIRED
07/05/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/05/2023 Residential Building REQUIRES RESUBMIT TC-RES-0623-05826
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

STRUCTURAL PLANS:

1. Provide a complete braced wall design, R602.10. Include braced wall panels within 10’ of each end and no more than 20’ between edges on sheet #3. Relocate the window openings for a minimum of two panels on this wall line.

SECTIONS - DETAILS:

1. Show a complete cross-section detail of the new exterior wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show with dimensions the exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5.

MECHANICAL PLANS:

1. Provide equipment specifications including the fan size or capacity, M1302.1.

ELECTRICAL PLANS:

1. Provide a Riser Diagram showing a sub panel and feeder size for proposed sub panel, NEC 225.30, E3403, Table E3704.2(1).

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
06/15/2023 Site Zoning REQUIRES RESUBMIT FROM: Iman Monshizadeh
PDSD Zoning Review Section
PROJECT: TC-RES-0623-05826 / Detached addition
Plot Plan Review (1st Review)
9712 E 5th St / R-1 Zone
TRANSMITTAL DATE: 06/15/2023


1. The minimum setback in the R-1 zone for the side and rear yards is 6’ or 2/3 * Height of the structure (whichever is greater). The proposed structure has a setback of 4’ from the west property line.
A Neighbor waiver will be required from the property owner located to the west of the subject parcel. Provide this signed statement on the site plan on the next submittal.

“My Name is ______________ and I am the owner of the property located at ____________. I have reviewed the site plan and I have no objections to structure being located or constructed ______ feet from the property line as depicted on the site plan

Signature:__________________

Date:_______________”

If neighbor waiver cannot be obtained, a Design Development Option will be required.

2. Show all structures including existing sheds and accessory structures on site plan on the next submittal.
3. Provide lot coverage calculations on the next submittal. An example of a lot coverage calculation can be found on this sample site plan: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

Resubmittal instructions: https://www.tucsonaz.gov/files/pdsd/pdfs/Resubmittals.pdf

For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov
06/12/2023 PDSD Application Completeness Express REVIEW COMPLETED