| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/29/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/29/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-05738 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Show the location of buildings, utility meters and gas, water, and sewer lines from property line to building, R106.1.1. SECTIONS - DETAILS: 1. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. Update detail 102/S3.0. PLUMBING PLANS: 1. Include the plumbing plan for review. 2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe bypassing the existing dwelling and show the water meter size. MECHANICAL PLANS: 1. Include the mechanical plan for review. ELECTRICAL PLANS: 1. Include the electrical plan for review. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 06/14/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0523-05738 520 S. Country Club Rd. - Zoning R-1 Interior Remodel and Bath Add (1st Review) TRANSMITTAL DATE: June 14, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. Based on the total building and vehicle use area of 3,161 and the lot size zone on land split TD-DIV-0423-00058, 13,019, the lot coverage calculation is not correct and should show 24.3%. 2. Until Land Split TD-DIV-0423-00058 is approved and recorded Zoning cannot approve this plan as shown. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/08/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 06/08/2023 | Site Engineering | REVIEW COMPLETED |