Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0623-05705
Parcel: 127042100

Address:
5036 E 3RD ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0623-05705
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/28/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/28/2023 Residential Building REQUIRES RESUBMIT TC-RES-0623-05705

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

SITE PLAN:

Provide a site plan showing dimensions of all buildings requiring a permit, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations.

STRUCTURAL PLANS:

1. Provide complete structural plans showing compliance with the IRC, R301.1. Show all proposed repairs and alterations with 2018 IRC compliance, R301.1.

2. The proposed Carport is sited within the 3’ fire separation distance determined from a line parallel and 3’ away from the west property line. Show compliance with R302.1 (City of Tucson Amended) by providing a wall with one-hour rated materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3, R106.1. This fire spread barrier is required from ground to roof and from end to end of the roof.

SECTIONS - DETAILS:

1. Provide a structure section showing the fire spread barrier features including materials, foundation, anchoring, and fastening to the roof assembly, R106.1.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
06/12/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0623-05705
5036 East 3rd Street – R-1
Carport (1st Review)

TRANSMITTAL DATE: June 12, 2023

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

The following comments are relative to an application for a Board of Adjustment variance (UDC 3.10.3).

The site is in the R-1 zone (UDC 4.7.8). A single-family residence is permitted in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9.

1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. Include the following information with your resubmittal:
a. Show the square footage of the lot, existing dwelling, proposed carport, and total under roof area.
b. Provide a lot coverage calculation (the area of the site occupied by buildings, storage areas, and vehicular use areas).
c. Show a dimension from the front street lot line to the centerline of 3rd Street, in addition to a revised dimension from the front street lot line to the edge of curb. Paving plan I-583 indicates that the distance between the front street lot line and the edge of curb is 12’-0” and not 9’-0” as depicted on the site plan.

2. Perimeter yard setbacks are based on a measurement from design grade to the highest point of an exterior building wall (UDC 6.4.5.B.1 and .2 and Figure 6.4.5-A). Per Tucson Unified Development Code (UDC) Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear perimeter yard setbacks are 6’-0” or 2/3 the height of the proposed exterior building wall, whichever is greater, measured from the lot line.

Based on an estimated wall height of 10’-9”, measured from design grade to the highest point of the imaginary carport wall, the required side perimeter yard setback is 7’-2”; proposed is 0’-8”. A DDO may be pursued if the carport posts are located at least 1’-0” from the west lot line.

A Board of Adjustment variance is required to allow this structure to be constructed with a setback less than 1’-0”. Contact Mark.Castro@tucsonaz.gov should you have questions regarding the Board of Adjustment variance process.

3. Detail 2 of Sheet A1.2 appears to show the carport overhang extending across the west lot line. Ensure the overhang does not extend beyond lot lines with your resubmittal.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
06/07/2023 PDSD Application Completeness Express REVIEW COMPLETED
06/08/2023 Site Engineering REVIEW COMPLETED