Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0623-05705
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/03/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-05705 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. A permit may not be processed until the construction plan set shows 2018 IRC compliance. SITE PLAN: The site plan shows a proposed structure is placed within the 3-foot fire separation distance to neighboring property line. As such the roof structure requires protection from the spread of fire. The plans require the inclusion of a 1-hour rated barrier with full length of the roof without openings. STRUCTURAL PLANS: 1. Provide a roof framing plan showing compliance with structural beam span ratings, R301.1. The 4 x 6 beam at a 12-foot span is not compliant for the minimum 20 PSF live load and 10 PSF dead load. SECTIONS - DETAILS: 1. Provide a complete wall section showing the fire spread barrier features including materials, foundation, anchoring, and roof fastening, R106.1. Show compliance with R302.1 (City of Tucson Amended) by providing a wall with one-hour rated materials prescribed in IBC Table 721.1(2), Items 15-1.1 to 16-1.3, R106.1. Update detail #2 including features from detail #3. 2. IBC Table 721.1(2) offers various options including 5/8” Type ‘X’ gypsum on both sides of the studs. An exterior weather rated covering is also required which may include T1-11. Also, 7/8” stucco may protect the wall studs. 3. Show the fire rated wall supported with a continuously reinforced foundation with stem for achieving the 6” minimum clearance between framing and ground (R317.1 item 5) or 2” clearance to a concrete floor. A load bearing wall may replace the need for support posts. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 09/18/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0623-05705 5036 East Third Street – R-1 Carport (2nd Review) TRANSMITTAL DATE: September 18, 2023 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Perimeter yard setbacks are based on a measurement from the design grade elevation to the highest point of an exterior building wall (UDC 6.4.5.B and Figure 6.4.5-A). Per UDC Table 6.3-2.A, the required side perimeter yard setback is six feet or two-thirds the height of the exterior building wall, whichever is greater. Ensure that a measurement from the design grade elevation to the highest point of the exterior carport wall is provided. Design Development Option (DDO) approval is required to reduce the side perimeter yard setback to 1’-0”. The DDO application and its requirements may be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf. Contact Georgia.Pennington@tucsonaz.gov should you have questions about the DDO process. 2. Ensure that a minimum setback of 20’-0” is provided as measured from the carport wall or posts to the front street lot line (UDC 6.4.5.C.1.a). DDO approval is also required to reduce this perimeter yard setback. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 09/15/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |