Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2023 Residential Building APPROVED
06/29/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/08/2023 Site Engineering REQUIRES RESUBMIT Project: TC-RES-0623-05621

Address: 3255 E GLENN ST

This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)

Please start a new FUP at our permit application web page:

https://tdc-online.tucsonaz.gov/#/home

NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided.

Instructions:

1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record

2. Locations -> Confirm the location is accurate to the project. Click “Next”

3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”

4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”

5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”

6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”

7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”

8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”

Contact Lianne Evans at lianne.evans@tucsonaz.gov, Stephen Blood at Stephen.Blood@tucsonaz.gov, or Loren Makus at Loren.Makus@tucsonaz.gov if you have any questions about the FUP.
06/29/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0623-05621
3255 East Glenn Street – R-2
Addition (1st Review)

TRANSMITTAL DATE: June 29, 2023

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

The site is in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .9, and .10.

1. Per Tucson Unified Development Code (UDC) 6.4.3.C.1.a, roofed areas, open on at least one side, which provide shelter to exterior areas and are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are not included in the lot coverage calculation.

Remove the existing porches from the lot coverage calculation.

2. Per Paving Plan U-2017-004, the front street property line is located one foot behind the edge of the existing sidewalk.

Based on the paving plan of Glenn Street, correct the site plan to show the correct front street property line location.

3. Show all structures on the site plan. A shade structure attached to the principal structure appears in Google Street View and aerial photography beginning in 2021. Zoning was unable to determine whether a permit was issued for this structure. If necessary, include the shade structure in this permit’s scope of work. The required side street perimeter yard setback is 10’-0” as measured from the east property line. Some sort of administrative process such as a DDO or a variance will be required to allow this shade structure to remain with a reduced setback.

4. The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

Perimeter yard setbacks are based on measurement from design grade to the highest point of the exterior wall (UDC 6.4.5.B and UDC Figure 6.4.5-A).

Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear perimeter yard setbacks are six feet or 2/3 the height of the proposed carport and patio posts, which is greater, measured from the property line.

Based on a wall height of 13’-2”, the required setback as measured from the east property line is 8’-9”; proposed setback is 5’-0”.

5. On April 21, 2023, the Mayor and Council effectuated several amendments to the UDC. Established and developing area setbacks no longer apply to new development. Per UDC 6.4.5.C.1.a, the required front street setback is 20’-0” as measured from the south property line; proposed appears to be 5’-4”.

A DDO is required to allow reduced front street (south) and side (west) perimeter yard setbacks. The DDO application and requirements may be found here: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. Contact Georgia.Pennington@tucsonaz.gov should you have questions regarding the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
06/05/2023 PDSD Application Completeness Express REVIEW COMPLETED