Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL POOL v.3
Permit Number - TC-RES-0526-02644
Review Name: RESIDENTIAL POOL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/29/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/15/2026 | Residential Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0526-02644 PROJECT: RESIDENTIAL POOL ADDRESS/PARCEL: 5982 E 28TH ST Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Swimming Pool and Spa Code, 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov COMMENTS: 1. Dimensions are to water’s edge, not coping’s edge. Please revise. 2. Under Gas Notes. There is a reference to the 2014 code, that is a typo and needs to be corrected to 2024. 3. Please remove all of the non essential notes on the site plan – ie, 90% of the recording information – that makes it very difficult to read. 4. Show the house/residence on the site plan and corresponding dimensions from the pool to the house. 5. Show your pool depth profile on the drawing. 6. Provide pool structural engineering as part of the submittal documents. 7. Are the lots being combined on this? There may be more comments upon resubmittal. Please upload your revised plans to TDC-Online with a revision letter outlining what has been revised on the doc set. Resubmittals will not be accepted without the revision letter that answers all of the above comments. |
||
| 09/29/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-0526-02644 Location: 2315 & 2301 E DRACHMAN ST Review Date: 9/29/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. The new pool permit, TC-RES-0526-02644, required approval and issuance of a lot line adjustment moving the property lines of 2315 & 2301 E DRACHMAN ST so that a principal structure is on the same parcel. 2. An overall site plan must be provided for the subsequent permits showing the proper address, changed lot lines, utilities, easements and related permits to clearly delineate where work is to be completed. 3. This permit will not be able to be approved until lot line adjustment (TD-DIV-0726-00048) is completed. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 09/21/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Drew Szentesy Planner PROJECT: TC-RES-0526-02644 2315 E DRACHMAN ST TUCSON, AZ 85719 Pool and Spa TRANSMITTAL DATE: 09/21/2026 This site is located within the R-1 zone (UDC 4.7.8). An single family dwelling is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9, & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Zoning will not be able to approve this until the lot line adjustment TD-DIV-0726-00048 is complete. As of now the pool is still part of a vacant lot and is not tied to a primary dwelling so it can not be approved. Also please specify if the pool will be under address 2315 or 2301 E Drachman after the lot line adjustment. If 2301 is correct then you will need to request an address change request through the sub records tab of the permit application. 2. Please include all details found in our basic site plan requirements. Our basic site plan can be found here for reference: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf 3. Please include property line dimensions of lot 10 if that is the lot the pool will be on after lot line adjustments. 4. Please include all existing and proposed structures on the lot in the site plan. 5. Please include setbacks between all structures and adjacent property lines. This includes the primary dwelling as well as the pool (which is already included). 6. Please include the dimensions, heights and materials of all existing structures including the height of the raised spa. 7. Please include lot coverage calculations by showing the following: a. Show square footage of the parcel b. Total square footage of all enclosed structures c. Total square footage of all vehicular use areas d. Add a lot coverage calculation, which is the percentage of the site occupied by enclosed buildings and vehicular-use areas The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Drew.Szentesy@tucsonaz.gov |
||
| 09/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |