Permit Number: TC-RES-0526-02586
Parcel: 135061320

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.3

Permit Number - TC-RES-0526-02586
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/22/2026 Residential Zoning APPROVED
07/17/2026 Residential Engineering NOT REQUIRED
07/22/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/21/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0526-02586 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2024 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance.

Provide a separate response letter addressing each comment with location of change on the plans.

PLANS:

1. Provide a shade structure Roof Framing Plan with compliant beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. The 4x6 beams are undersized.
2. Clarify the rafter size for supporting live and dead structural loads (Table R802.4.1(1)). Update detail B & C showing 2x8 joists consistent with the Roof Framing Plan on sheet 4.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
07/17/2026 PDSD Application Completeness Express REVIEW COMPLETED