Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0526-02573
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/15/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | If you have questions regarding this Review, please contact Juan Quintana at juan.quintana@tucsonaz.gov Please resubmit addressing the following comments: 1) The 1" pipe for the gas meter to the Furnace T off is undersized for the given length and appliance demand. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe), or Manufacturer’s sizing requirements. 2) Include pipe material (Black Iron, Poly) for all lengths. G2401.1, G2413.1, R301.1. Note: Indicate any changes of material from one section to another (e.g. underground poly -> surface BI) 3) Include the size of the pipe size, material, and length from Main gas line T off to furnace. |
||
| 05/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |