| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/03/2026 | Residential Engineering | APPROVED | REF: TE-FPU-0626-00227 | ||
| 06/03/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/27/2026 | Residential Building - Standard | REQUIRES RESUBMIT | Please review the comments below and resubmit once they have been addressed. 1. The structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by protecting the structure placed within 3 feet of the property line in compliance with IBC Table 721.1(2). Include a one hour rated wall below the roof edge with foundation along the full length of structure near the property line or relocate the structure out of the fire separation distance. 2. Also, a roof projection (overhang beyond beam) may not extend closer than 24” to the adjoining (neighboring) property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). |
||
| 05/21/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0526-02552 5933 E Sahuaro Ranch Dr, Tucson, AZ 85712 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: May 21st, 2026 This site is located in the R-2 zone (UDC 4.7.9). An attached single-family residence is a permitted use in this zone subject to use-specific standards 4.9.7.B.6, .8 and .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The site plan provided is not sufficient. Please provide a site plan that meets the requirements found at the following link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples 2. (Comment) Zoning is unable to locate permits for the existing shade structure. If permits for the existing shade structure can not be located, the proposed shade structure will be reviewed as new construction. 3. (Comment) 5933 E Sahuaro Ranch Dr is zoned R-2. The minimum perimeter yard setback in the R-2 zone is 5’. The indicated setback for the proposed shade structure is 1’ from the north, west, and south property lines. Either comply with the minimum required setback or apply for a Design Development Option (DDO) per UDC 3.11.1 to reduce the minimum required setback. If you wish to move forward with the DDO, please submit a DDO application under the Zoning Modification sub-record that has been created. Ensure that the application includes a site plan that meets the requirements found in Comment 1. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 05/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |