Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADU v.1
Permit Number - TC-RES-0526-02496
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/29/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/14/2026 | Addressing Validation | REQUIRES RESUBMIT | For questions: PDSD-Permits@tucsonaz.gov The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for this ADU. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit. Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf |
||
| 05/18/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-0526-02496 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. 3. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3. SECTIONS - DETAILS: 1. Show exterior wood siding, sheathing, water-resistive barrier and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. Update detail #4/A-8. 2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. Update detail #5, 6 & 7/A-8. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A two or three-bedroom dwelling under 1501 SF requires a 45 CFM continuous setting. 2. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1. PLUMBING PLANS: 1. Provide ¾” water pipes (hot & cold) downstream from the water meter supplying the branch lines for controlling flow rates at 17 GPM, Table P2903.7(1). 2. Show each gas pipe segment sized in conformance with Table G2413.4(1). Show the total developed length and demand. ELECTRICAL PLANS: 1. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 2. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include: 1. Drinking water coolers 2. High pressure spray washing machines 3. Sump pumps 4. Dishwashers 5. Electric ranges 6. Wall-mounted ovens 7. Counter-mounted cooking units 8. Clothes dryers 9. Microwave ovens 3. Provide GFCI protection for receptacle outlets and HVAC equipment after September 1, 2026. E3902.14. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 05/29/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-0526-02496 Location: 2115 N TUCSON BL Review Date: 5/29/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. The property is in the recognized City of Tucson Wilson Wash. A floodplain use (FPU) with elevation certificate permit has been created for this building permit, TE-FPU-0526-00209. 2. Successful submittal approval of a grading permit (DP) and floodplain use permit (TE-FPU-0526-00209) will be required prior to issuance of this building permit. 3. Follow instructions on floodplain requirements for the DP & FPU permit. Changes Required for Building Permit Resubmission: 4. Indicate with a general note, that the entire site resides in the 100-yr recognized City of Tucson Wilson Wash floodplain. 5. Include the finished floor elevation (FFE) of the proposed structure. The BFE was calculated at 2429.7-FT NAVD 88, therefore, the required FFE must be at a minimum 2430.7-FT. Provide the determined FFE on the site plan in the same location as the proposed structure. 6. The new dwelling requires an exterior accessible route that shall conform to 2017 ICC A117.1 Sections 402 and 403 and City of Tucson Inclusive Home Design Ordinance. Water draining from roof shall not interfere with exterior accessible route. Please update site plan to include a general note regarding City of Tucson requirements for Inclusive Design. Show the accessible route on the site plan. 7. Provide the dimensions for the easement on the West property line. Easement indicated on Final Plat: https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-07032&0 If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 05/18/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0526-02496 2115 N Tucson Bl., Tucson, AZ 85716 ADU (1st Review) TRANSMITTAL DATE: 05/18/2026 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Submit a landscape plan on the revised site plan. City of Tucson Ordinance No. 12219 is effective as of January 1, 2026. This ordinance is an amendment to the Unified Development Code. UDC Article 7, Section 7.6.10 and requires landscaping for all new single family residential, middle housing development, and accessory dwellings. It is not necessary to hire a landscape architect. The landscape plan is to be applied directly onto the site plan and includes labeling the species of plant and trees and explaining how they will be watered and maintained. Here is a link that breaks down the landscape requirements and provides additional clarification on how to submit the landscape plan: https://middle-housing-cotgis.hub.arcgis.com/pages/Residential-Landscaping-Code 2. Please make the redlined changes on Sheet A.1. As of January 1, 2026, rear and side setbacks for interior lots changed from 6’ or 2/3 the height of an exterior wall, whichever is greater, to 5’. Additionally, the sheet shows two blocks containing the same information. 3. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label a 4’-wide accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. 4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. |
||
| 05/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |