Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0526-02479
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/21/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0526-02479 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance with component sizes. Provide a response letter on separate file when submitting the updated construction plan set. Structures built without a permit may require alteration for building code compliance. Construction plans are required for determining code compliance before a permit can be issued for the inspection. Provide a clear and concise construction plan set. Review the sample drawings for a wooden Carport which are similar to the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the location of the proposed porch/patio covers, R106.1.1. STRUCTURAL PLANS: 1. Show the size and location of each support footing, R106.1.1. 2. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads, Table R602.7(3). 3. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads, Table R802.4.1(1). SECTIONS - DETAILS: 1 Show the minimum 12”x12” by 12” deep #4 reinforced footing in undisturbed ground supporting each post with 1” gap post base hardware, R403.1. 2 Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1. 3 Provide structural roof sheathing size and fastening in compliance with Table R602.3 (1). 4 Note the location and size of ledger anchorage to a load bearing wall, R606.11. Remove any stucco behind the ledger. 5 Identify all fasteners for wind loading compliance. Show post cap hardware with appropriate uplift capacity, R802.11. ELECTRICAL PLANS: 1. Show any electrical alterations. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 05/15/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0526-02479 Project: Addition/Alteration Location: 1732 N DODGE BL Review Date: 5/15/2026 Reviewer: Joe Macaulay – Civil Engineer - Site Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Site Engineering Review Comments: 1. Please provide a site plan within the plan set that shows/dimensions the entire lot boundary and labels the proposed structure/work for this particular permit. See the provided link for site plan examples https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples 2. Please provide stamped plans for permit submission. If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov |
||
| 05/18/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0526-02479 1732 N Dodge Bl., Tucson, AZ 85716 As-Built Pergola, Patio and Porch (1st Review) TRANSMITTAL DATE: 05/18/2026 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The plans provided do not include a site plan and include other projects. Please submit a site plan on one sheet that meets the requirements show in the Full site plan shown in the examples at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples . Please make sure the project scope is explained clearly on the site plan. 2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code This now includes the UDC amendments adopted via Ordinance No. 12219 effective January 1, 2026. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov |
||
| 05/13/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |