Permit Number: TC-RES-0526-02433
Parcel: 116120170

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0526-02433
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2026 Residential Zoning APPROVED
05/29/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/14/2026 Addressing Validation REQUIRES RESUBMIT For questions: PDSD-Permits@tucsonaz.gov

The permit and plan show to be for a Duplex and requires each unit to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new addresses for this Duplex. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit.

Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
05/14/2026 Residential Building REQUIRES RESUBMIT TC-RES-0526-02433
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings.

Provide a separate response letter addressing each comment with location of change on the plans.

SECTIONS - DETAILS:

1. Garages beneath habitable rooms require separation from all overhead habitable rooms by not less than 5/8” type X gypsum board or equivalent. Also, ½” GWB is required on supporting walls, Table R302.6.
2. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). Detail the separating wall.

MECHANICAL PLANS:

1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1.
2. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1.

ELECTRICAL PLANS:

1. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5.
2. .
3. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include:
1. Drinking water coolers
2. High pressure spray washing machines
3. Sump pumps
4. Dishwashers
5. Electric ranges
6. Wall-mounted ovens
7. Counter-mounted cooking units
8. Clothes dryers
9. Microwave ovens
4. Provide GFCI protection for receptacle outlets and HVAC equipment after September 1, 2026. E3902.14.

OUTDOOR LIGHTING CODE

1. Clarify the Outdoor Lighting Calculation with the proposed fixtures on the property, OLC 401.3.

Please contact the plans reviewer if you have any questions:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
05/29/2026 Residential Engineering REQUIRES RESUBMIT Permit: TE-FPU-0526-02433 – Duplex
Location: 1212 W DELAWARE ST
Review Date: 5/29/2026

A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal.

Residential Engineering Comments:
1. The property is in the recognized City of Tucson El Rio Wash. A floodplain use (FPU) with elevation certificate permit has been created for this building permit, TE-FPU-0526-00210.
2. Successful submittal approval of a grading permit (DP) and floodplain use permit (TE-FPU-0526-00210) will be required prior to issuance of this building permit.
3. Follow instructions on floodplain requirements for the DP & FPU permit.

Changes Required for Building Permit Resubmission:
4. Indicate with a general note, that the entire site resides in the 100-yr recognized City of Tucson El Rio Wash floodplain.
5. Include the finished floor elevation (FFE) of the proposed structure. The finished floor elevation will need to be determined from the Base Flood Elevation (BFE) provided in a Flood Plain Report. Provide the determined FFE on the site plan in the same location as the proposed structure.
6. Per the City of Tucson Inclusive Home Design Ordinance https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label the accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in 2017 ICC A117.1 Sections 402-403, including the minimum 4ft-width, slope and composition materials. Please also label the accessible entries and demonstrate that the accessible entries meet this requirement.

If you have any questions or concerns, please contact Joe Macaulay.
Joe.Macaulay@tucsonaz.gov
05/14/2026 PDSD Application Completeness Express REVIEW COMPLETED