| 05/14/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/11/2026 | Addressing Validation | REQUIRES RESUBMIT | For questions: PDSD-Permits@tucsonaz.gov. A secondary dwelling requires to be separately addressed, and the location does not appear to have units attached to the address. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. Note, a resubmittal and address change is required. |
||
| 05/11/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-0526-02425 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2024 IRC with amendments and building ordinances for all dwellings. Place the 2024 IRC reference on sheet A-1. Provide a separate response letter addressing each comment with location of change on the plans. GENERAL COMMENTS: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Building-Codes 1. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. 2. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. Update detail #2 on sheet 3. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. 2. Identify the device model number providing an adjustable setting and note the minimum continuous or intermittent setting for providing whole-house mechanical ventilation, R303.4; N1103.6 & M1505.4. PLUMBING PLANS: 1. The gray water system is not required for the ADU. Consider a less costly and ready to use system using a dual stand pipe washer box as illustrated at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation 2. Show the water heater rating/capacity for consistence with the electrical circuit size, R106.1.1. ELECTRICAL PLANS: 1. Remove the 2018 code reference from the first note. 2. Show a surge-protective device (SPD) as an integral part of or placed immediately adjacent to the service equipment, E3606.5. 3. Remove the receptacle from the exterior face of island cabinet where below the countertop, E3901.4.2. 4. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include: 1. Drinking water coolers 2. High pressure spray washing machines 3. Sump pumps 4. Dishwashers 5. Electric ranges 6. Wall-mounted ovens 7. Counter-mounted cooking units 8. Clothes dryers 9. Microwave ovens 5. Provide GFCI protection for receptacle outlets and HVAC equipment after September 1, 2026. E3902.14. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 05/12/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0526-02425 (1st Review) Project: New ADU Location: 811 W IDAHO ST Review Date: 5/12/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Site Engineering Review Comments: 1. As the proposed development is a new dwelling (ADU, SFR, Duplex, Etc), Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. a. Refer to Technical Standards Manual Section 7-01.4.3 for sidewalk/pathway specifications including the minimum 4ft-width and composition minimums. b. Action Items: Provide a width call-out, proposed slope, and label the walkway as the “Accessible Route” leading to the new home entrance If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 05/14/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-0526-02425 811 W IDAHO ST ADU (1st Review) TRANSMITTAL DATE: 5/14/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). An accessory dwelling unit (ADU) is a permitted use in this zone (Table 4.8.4) subject to Use Specific Standards 4.9.7.B.6, .8, & .12 and 6.6.3. Comment 1: Please include landscaping details on the site plan in the next submission. Per UDC 7.6.8., all new single family residential, middle housing development, and accessory dwelling units require the following landscaping: One canopy tree for every 1,000 SF of gross floor area. This rounds up to one (1) tree for projects under 1,000 SF. Vegetative groundcover within the front yard setback. The area for this can be calculated by multiplying the length of the street frontage (67.5 feet for this project), subtracting the width of the existing driveway, and then multiplying by five. Please label and include dimensions for the groundcover area on the site plan. All plant material used for landscaping must be selected (and drought-tolerant) from the adopted plant list located in Section 5-02.5.0 of the Technical Standards Manual found at https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-11367 This code section also contains plant and tree maintenance. Comment 2: Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Please draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 05/11/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |