Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0526-02342
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/07/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have questions regarding this review, please contact PDSD-Permits@tucsonaz.gov. Parcel/addressing issue. The site plan shows to contain multiple units, and each dwelling structure should be addressed with a unit number. The location does not have units attached to the address. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. After address/units have been added or verified you'll need to submit an address change request through sub records to update this record along with a new site plan that shows the corrected addressing. |
||
| 05/11/2026 | Residential Building | REQUIRES RESUBMIT | Provide a complete construction plan set similar to TC-RES-0226-00953 after all Zoning updates. | ||
| 05/13/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0526-02342 Project: Duplex Location: 879 W PENNSYLVANIA ST Review Date: 5/13/2026 Reviewer: Joe Macaulay – Civil Engineer - Site Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Site Engineering Review Comments: 1. Per the City of Tucson Inclusive Home Design Ordinance, show and label both the accessible entrances and paths on the site plan. Ensure the route meets accessibility standards as articulated in 2017 ICC A117.1 Sections 402-403, including the minimum 4ft-width, slope and composition materials. If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov |
||
| 05/13/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-0526-02342 879 W PENNSYLVANIA ST BLDG 2 Duplex (1st Review) TRANSMITTAL DATE: 5/13/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). Middle housing projects up to four units is a permitted use in this zone (Table 4.8.4) subject to Use Specific Standards 4.9.7.B.4-.6, .8, & .9. Comment: Per Middle Housing Ordinance 12219, front yards are permitted one driveway no more than 20 feet in width and up to 400 square feet of additional vehicular use area. Four hundred square feet typically accommodates two standard parking spaces. The remaining parking spaces should be placed in the side or rear yard. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 05/07/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |