Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0526-02326
Parcel: 123052740

Address:
2220 E GRANT RD

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.3

Permit Number - TC-RES-0526-02326
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/28/2026 Residential Building - Standard REQUIRES RESUBMIT Please review the comments below and re submit.
1. Please provide an electrical panel schedule naming all circuits along with amperage and gauge.
2. Update code reference on cover page to reflect current code year on the legal document.
3. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3.
4. Show the HVAC system size accordance with M1401.3, M1601.1
5. Calculate CFM being provided to the space.
07/30/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner
PROJECT: TC-RES-0526-02326
2220 E Grant Rd. Tucson, AZ 85719
Bedroom Addition (3rd Review)

TRANSMITTAL DATE: 07/30/2026

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Change the rear setback from 10’ to 5’. (UDC Table 6.3-2.A.) This places the moveable shed outside of the setback.

2. Add the easement as shown along the rear lot line on the Catalina Vista Subdivision found at https://maps-and-records.tucsonaz.gov/subdivisions/details/1063 .

3. Once corrections have been made, submit the following:

a. Revised Site Plan
b. Construction Plans
c. A response letter addressing all staff review comments.

4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov
07/24/2026 PDSD Application Completeness Express REVIEW COMPLETED