Permit Number: TC-RES-0526-02326
Parcel: 123052740

Address:
2220 E GRANT RD

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0526-02326
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/26/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/26/2026 Residential Building - Standard REQUIRES RESUBMIT 1. Please provide an electrical panel schedule showing new circuit for addition.
2. Show light fixtures with fire-resistance-rated construction when recessed in fire-resistant ceiling material, E4004.1
3. General note 1 on page 9 states plan is for reference only, submit contractors system design per your plans.
4. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material.
5.Provide CFM for supply in addition.
6. General note 1 on page 10 states plan is for reference only, submit contractors system design per your plans.
7. Submit plans with correct code references on page 1.
8.Provide a Roof Framing Plan showing the beams and rafters sized for supporting live and dead structural loads usually obtained from the manufacturer. An engineer’s calculation, design, and seal for a performance design is required when minimum sizes are not code compliant with the IRC, R301.1
05/11/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: TC-RES-0526-02326

2220 E GRANT RD

Bedroom addition (1st Review)

TRANSMITTAL DATE: 5/11/26

Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9.

Comment 1: Please include the following information on the site plan upon next submittal:

Label and add driveway/vehicular use area(s) to the lot coverage calculations

Property owner information

Existing walls/fences (include location and height)

Zoning designation of this property and those adjacent (R-1)

Comment 2: Please provide an interior floor plan of the house including the proposed addition.

Comment 3: Based on aerial images of the site from 2024, there is a small accessory structure in the backyard of the property. Please include this on the site plan and in the lot coverage calculations. Label the structure, include setback measurements, dimensions, and square footage. If the structure is no longer there, please still include on site plan with a note it has been removed/demolished.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code

If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
05/07/2026 PDSD Application Completeness Express REVIEW COMPLETED