Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0526-02300
Parcel: 112061920

Address:
2602 N WILSON AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL FENCE/WALL v.1

Permit Number - TC-RES-0526-02300
Review Name: RESIDENTIAL FENCE/WALL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2026 Residential Building NOT REQUIRED
05/08/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/05/2026 Residential Engineering REQUIRES RESUBMIT Permit Activity Number: TC-RES-0526-02300 (1st Review)
Project: Fence around front yard of house
Location: 2602 N WILSON AV
Review Date: 5/5/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

Site Engineering Review Comments:
1. This property located at 2602 N WILSON AV is located entirely within a FEMA AE floodplain associated with the Wilson Avenue wash that runs S to N towards the West of this subject property. As this is a residential building permit for a fence/wall located within a designated flood hazard/floodplain, it will require the submission of a separate floodplain use (FPU) permit application. The floodplain use (FPU) permit is an entirely separate permit that can be submitted within the sub-records of this residential permit through TDC Online.
a. As the property is subject to floodplain standards/regulations – it will be required that proper flood spacing be provided for the new proposed fence. It will be required that a fully dimensioned fence construction detail be provided in the plan set to show that requirements are addressed.
b. Based on current Flood Insurance Studies (FIS) data, it looks that the base flood elevation (BFE) for the property is ~2411.1 FT. In compliance with floodplain regulations – it is required that the bottom of the fence from natural grade, up to the base flood elevation be free and clear of all obstructions. Existing elevations for where the fence will be placed will need to be determined to determine the total necessary free space.
c. Include a statement on the plan set that states “Wooden fence to remain clear from natural grade up to the determined base flood elevation – XX inches high.” XX inches will be based on existing elevations which will need to be determined prior to submitting of any plans.
d. For resubmission of this residential building permit and the first submission of the floodplain use permit – adherence to these requirements will need to be demonstrated.

2. Site Engineering will be unable to approve permit TC-RES-0526-02300 until the associated FPU permit is approved. It is recommended that the FPU permit process be started and achieve approval and issuance prior to the resubmission of this permit to ensure no project delays and review overlap.


If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
05/08/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0526-02300 – Residential Building – Fence
2602 N WILSON AV TUCSON, AZ 85719 (R-1 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: May 08, 2026

This site is in the R-1 Residence Zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 for 1 unit;

Plan review for the above referenced fence has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: The site plan(s) provided are incomplete.

Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/plan-samples/basic-site-plan-spanish.pdf

Specifically:

A. Draw, label and dimension everything that exists on the property to a scalable drawing graphic (examples include the principal residence, porches, breezeways, sidewalks, driveways, parking spots, walls, fences, ramada, shed, carport, shade sail, cistern, pool, guest house, sleeping quarters, accessory dwelling unit) and provide dimensions of any structure as it relates to nearby structures and property lines and provide the heights (measured from above finish grade to top of wall, etc.) of those structures that run parallel-perpendicular to any nearby adjacent property lines.

Draw, label and dimension existing wall and fence (from permit T13BU00812) and label the existing heights of each fence and wall. Provide dimension of existing wall along east property line as it relates to the 5’-0” easement.

Additionally, it appears a wall already exists along the east portion of the driveway, yet a new wall is appears to be proposed in the same location. Indicate if a portion of the existing wall is being replaced and if so, indicate the length of how much is being removed and label this portion of the wall ‘existing wall to be removed’.

B. Refer to Pima County’s website https://gis.pima.gov/maps/detail.cfm?&parcel=112061920 to locate and provide the parcel number, legal description, subdivision name, book and page numbers, township-section and range, sequence number on the plot plan.

C. Draw, label and dimension all property lines, (provide property line lengths) and the 5’-0” wide easement along the east property line to be reflective in the property title report. Refer to Pima County’s website https://maps-and-records.tucsonaz.gov/subdivisions/details/1271 . The math of the property line lengths will produce the total parcel square footage.

D. As a result of not producing a site plan with inaccurate property line lengths, a lot coverage calculation table was not provided. Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are NOT included in the calculation and per UDC Article 6.4.3.B.3.b vehicular use areas measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved, are included in the lot coverage.

Calculate (measure) square footage of every enclosed (NOT open structures like a porch, ramada, carport) structure on site and all vehicular use area (driveway, parking, turnaround, backup) and input into lot coverage calculation table. A carport would be calculated under vehicular use area. These separate ‘category numbers are added together and divided by the total parcel square footage to produce the lot coverage percentage that demonstrates compliance (or not).

E. Provide R-1 zoning labels on the east, west and north sides of this parcel (including this parcel) and R-2 zoning label to the south.

F. Provide missing architectural site plan scale, corresponding graphic scale and north arrow.

G. Label the heights of the proposed walls and gate.

2. COMMENT: Two site plans were provided. Combine both drawings to be on one pdf site plan drawing.

3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents associated with this permit

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
05/04/2026 PDSD Application Completeness Express REVIEW COMPLETED