Permit Number: TC-RES-0526-02295
Parcel: 123120790

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0526-02295
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/14/2026 Design Review - Standard NOT REQUIRED NPZ review is not required since bedroom addition in the rear is not visible from the public right-of-way. Alleway in the rear is not a named alley.
05/05/2026 Residential Engineering NOT REQUIRED
05/26/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/26/2026 Residential Building - Standard REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0526-02295
ADDRESS/PARCEL: (1051 E HAMPTON ST TUCSON, AZ 85719)
Submit your revised reports along with a response letter which states how all Building Review Section comments were addressed. The submitted documents were incomplete, and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov.
COMMENTS:
1. Provide a foundation plan that shows conformance with R403.1 and R506.3.3
2. Provide a complete roof and wall framing plan. Include wall section details, and built-up roofing details R106.1
3. The provided elevations do not match the plans. Elevations show a door on the East side where the plans show a window. The North elevation shows a window where the plans show none. The West elevations show no openings where the plans show a window.
4. Show compliance with emergency escape requirements R319.2 - R319.2.3. Note: a window with an A/C unit mounted in it cannot be used for emergency exit.
5. Provide an electrical load calculation determining the total demand on the existing panel to show it can handle the additional load. E3602.2
6. Example plans can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/addition_sample.pdf
7. Please correct and resubmit.
05/08/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0526-02295 – Residential Building – Addition of home office
1051 E HAMPTON ST TUCSON, AZ 85719 (NR-1 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: May 08, 2026

This site is in the NR-1 Residence Zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 for 1 unit;

Plan review for the above referenced addition in the form of a home office has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: The scope is entitled home office, but the plan view graphics and lot coverage table depict/reference a bedroom. Clarify what the addition is specifically intended for and indicate on the existing residence floor plan where all the existing bedrooms are. Refer to Comment #7 (below).

2. COMMENT: Draw, label and dimension existing parking and vehicular use area. The total vehicular use area (driveway, backup areas, parking stalls) is part of the lot coverage calculation (total vehicle use area + total enclosed architecture on-site / total lot square footage = % coverage).

3. COMMENT: The lot is 80’-0” x 150’-0” = 12,000 square feet (11,924 sf currently shown). Update lot square footage and lot coverage table accordingly.

4. COMMENT: Provide a setback table that includes front yard setback = 20’-0” (east or south property line*), side yard setback = 10’-0” (east or south property line*), and the north and west interior yard property line setbacks at 5’-0”. *Owner decides which is which but communicate choice on site plan.

5. COMMENT: The site plan provided is incomplete.

Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/plan-samples/basic-site-plan-spanish.pdf

Specifically:

A. Provide NR-1 zoning labels on all four sides of this parcel.

B. The scale noted is not an architectural scale. Update label and plan graphics to 1/16” = 1’-0”.

C. Provide missing legal description (MONTEREY AMENDED LOTS 19 & 20 BLK 31)

D. Provide more specific labeling of the existing structures on-site to describe what those buildings are being used for.

6. COMMENT: The site is in the Neighborhood Preservation Review (NPZ) overlay. Review per https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-4427 . A NPZ review may be required since the project is within the NPZ overlay and proposed exterior modifications to the structure are visible from the right of way.

If the design reviewer deems further information will be required, see below and for questions about the NPZ process please contact gabriel.sleighter@tucsonaz.gov

7. COMMENT: As this property is in the NR-1 zone, please include a complete floor plan of the house to show you are following UDC 4.9.7.B.7.

For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.

8. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

If deemed applicable by the Design reviewer, NPZ Application: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents associated with this permit (all drawings in sheet index on one pdf file)

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
05/04/2026 PDSD Application Completeness Express REVIEW COMPLETED