Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0525-02662
Parcel: 118121190

Address:
204 E 23RD ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0525-02662
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2025 Residential Building - Standard APPROVED
06/17/2025 Site Engineering - Standard NOT REQUIRED
06/23/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/23/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0525-02662
204 E 23RD ST. – R-2
New porch addition and storage closet (1st Review)

TRANSMITTAL DATE: June 23, 2025

COMMENTS: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.


1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’.
b. The north/south property line is not correct. Per the South Park Addition final plat found at: https://maps-and-records.tucsonaz.gov/subdivisions/details/552, the correct distance is 150’.
c. Provide a lot coverage calculation that meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements.
d. Provide a dimension from the centerline of 5th & 23rd to the face of curb, and from the face of curb to the applicable property line. Per Construction Plan I-523, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-523, sheet 8, the distance from center line of 5th Ave to the face of curb is 20’ and from face of curb to the west property line is 19.6’ and sheet 2 the distance from center line of 23rd St to the face of curb is 19.25’ and from face of curb to the north property line is 12’.
e. Show all utility lines on the plot plan.
f. Indicate the zoning of this parcel and all adjacent parcels on the plot plan

2. Per UDC Article 6.4.5.C.1.b the minimum side street perimeter yard setback is 10’-0”, proposed side street perimeter yard setback is 7’-8”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
05/21/2025 PDSD Application Completeness Express REVIEW COMPLETED