Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0525-02597
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/29/2025 | Addressing Validation | REQUIRES RESUBMIT | The full property address needs to be written on each page of the site plan set. Please resubmit with the address included after all other reviews are complete. | ||
| 09/23/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0525-02597 2nd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Note the 2018 IRC reference on the plans. Provide construction plans with sheet numbering in a single PDF file. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample Addition plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the location of utility lines for water, electric and sewer from property line to building, R106.1.1. Identify the utility line connection points. PLANS: 1. Show the functional name of each existing adjacent room, R106.1.1. Existing bedrooms with removed windows require code compliance for egress, R310. Include the bedroom door or window location and size providing egress to the exterior. 2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)). These rafters require sufficient depth for R-30 insulation including the air-impermeable rigid insulation material placed against the roof sheathing. SECTIONS - DETAILS: 1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. 3. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. The total roof insulation for this addition size is R-30. Identify the ventilation requirements and insulation types for complying with the condensation control issues. PLUMBING PLANS: 1. Provide complete plumbing alterations, R106.1.1. Include water supply lines, drain lines and drain vent locations. MECHANICAL PLANS: 1. Provide complete mechanical alterations, R106.1.1. Show an exhaust fan if used for moisture ventilation. ELECTRICAL PLANS: 1. Provide complete electrical alterations, R106.1.1. Include the location of switches, lights and receptacles. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show compliance with the energy code requirements, N1102.1. Identify insulation and window R and U values for compliance. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 10/01/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0525-02597 6526 E Calle Bootis Bathroom Addition (1st Review) TRANSMITTAL DATE: 10/01/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5-.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Provide a new plot/site plan. Although the submitted materials provide the project scope, the current site plan is insufficient to conduct a formal Site Zoning Review. For just one example, the submitted site plan does not show all existing structures. If any of these structures, including the shade structure located near the west property line and the cargo container located in the driveway, are no longer existing, a note needs to be included for each. For further information regarding plot plan directions, please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example and include all of the relevant information. Additionally, the Unified Development Code (UDC) can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code Note: An image of Lot 10, Block 10 Terra Del Sol, extracted from the Assessor’s Record Map, may be accessed here: https://www.asr.pima.gov/ParcelData/Map/Arm/MP11/M11058_B10.PD 2. Please submit the following information on the newly revised plot/site plan tailored to the subject lot: a. On the newly revised site plan, provide the location, uses and square footage of the existing dwelling, new bathroom addition, vehicular areas, and all other structures as shown in the sample plot plan (discussed above). b. Calculate the lot coverage by adding the square footage of the following: i. Existing dwelling ii. New bathroom Addition iii. Per UDC Article 6.4.3.B.3.b, “Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage”. Then, divide the total sq. ft. by the lot size of 9,577 sq. ft. The lot size was obtained from the following link: https://gis.pima.gov/maps/detail.cfm?&parcel=135021880 3. The plot plan instructions (see Comment #1) require specific measurements from the street. Show the measurement from the center line of E Calle Bootis (16’) to the front of the curb (street facing). Show the distance from the front of the curb to the property line (9’). This information (street paving plans) is provided at the following link by the Department of Transportation and Mobility: http://maps-and-records.tucsonaz.gov/construction-plans/details/I-748A , paving profile 1-78A_007 from the list. 4. Add the front perimeter setback of the subject lot (20’ per the R-1 zoning). The west and rear perimeter setbacks are 6’ need to be shown. The east setback is 10’ since the subject lot borders two streets. 5. Attache elevation drawings of the addition (North, South, East and West). Show the height of the addition from the design grade (not top of foundation) to the point where the exterior wall meets the roof. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 08/29/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |