Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0525-02547
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/26/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/31/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0525-02547 3rd PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Provide a complete construction plan set with all pages in one file. The plan set file must contain the site plan, framing plan and elevation detail. Provide a response letter on separate file when submitting the updated construction plan set. Provide a clear and concise construction plan set. Review the sample drawings for a wooden Carport which are similar to the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location of the electrical line to the service panel, R106.1.1. An overhead line may require relocation for providing required clearance. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 01/26/2026 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-RES-0525-02547 – Residential Building – Attached Carport 1121 W Speedway Bl Tucson, AZ 85745 (R-2 Zoning) Building Plan Review – 2nd Review TRANSMITTAL DATE: January 26, 2026 This site is in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. Plan review for the above referenced attached carport has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. 1. COMMENT: The site plan provided is missing / has information that needs to be updated: A) The property lines are not labeled and need to have the correct property line lengths. Refer to https://www.asr.pima.gov/ParcelData/Map/Arm/MP06/M06007_B07.PDF B) Label W Speedway Bl C) Provide a North Arrow (in the correct direction) D) Draw and label setbacks: 5-0” for side and rear yards and 20’-0” for the front yard setback. E) Provide missing zoning label for this property and surrounding properties (R-2). F) Provide the following information as it relates to the legal description, etc.: Parcel 116-17-131A RIVERSIDE PARK LOT 15 BLK 7 EXC N30' (RD 8169/219) RIVERSIDE PARK Book 6, Page 7 Township 14S, Range 13E, Section 11 2. COMMENT: Per UDC 6.6.3.C. standard, detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and front street lot line, except for shade structures or carports not over 400 square feet in floor area, terraces and steps not over three high above the natural grade, paved areas, and fences or walls. Carport is currently dimensioned as 30’-0” x 14’-0”, totaling 420 square feet. Adjust design to meet standard. Should you decide to stay with the current square footage, a Board of Adjustment Variance will be required. Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved. See below for more information on the B/A Variance process. 3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 12/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |