Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.2
Permit Number - TC-RES-0525-02537
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/18/2025 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0525-02537 ADDRESS/PARCEL: (3225 N TUTTLE AV TUCSON, AZ 85705) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Please provide a lag-bolt connection up-lift calculation for this specific PV system, or provide an engineer’s calculation. R301.1, R324.4. 2. Provide calculations showing total roof equipment weight for this PV system is a maximum per attachment point of 45lbs or less, and distributed weight is 4psf or less. R324.4.1.1 3. Please combine all sheets into a single PDF document. Include the Plot Layout, One Line Diagram, Three Line Diagram, and Roof Panel Layout Plan. 4. Please Resubmit Contact Sean Severson with any questions: sean.severson@tucsonaz.gov |
||
| 06/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |