Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.2
Permit Number - TC-RES-0525-02536
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/17/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/17/2025 | Light Residential Building Review (OIP) - Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-RES-0525-02536 ADDRESS/PARCEL: (7910 S TARBELA AV TUCSON, AZ 85747) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Please provide a lag-bolt connection up-lift calculation for this specific PV system, or provide an engineer’s calculation. R301.1, R324.4. 2. Provide calculations showing total roof equipment weight for this PV system is a maximum per attachment point of 45lbs or less, and distributed weight is 4psf or less. R324.4.1.1 3. Provide ESS disconnecting means within sight of the battery, 706.7. Please show this on both line diagrams, and not just in the notes section. 4. Please combine all sheets into a single PDF document. Include the Plot Layout, One Line Diagram, Three Line Diagram, and Roof Panel Layout Plan. 5. Please Resubmit Contact Sean Severson with any questions: sean.severson@tucsonaz.gov |
||
| 06/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |