Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0525-02536
Parcel: 141166180

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.2

Permit Number - TC-RES-0525-02536
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/17/2025 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0525-02536
ADDRESS/PARCEL: (7910 S TARBELA AV TUCSON, AZ 85747)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.
COMMENTS:
1. Please provide a lag-bolt connection up-lift calculation for this specific PV system, or provide an engineer’s calculation. R301.1, R324.4.
2. Provide calculations showing total roof equipment weight for this PV system is a maximum per attachment point of 45lbs or less, and distributed weight is 4psf or less. R324.4.1.1
3. Provide ESS disconnecting means within sight of the battery, 706.7. Please show this on both line diagrams, and not just in the notes section.
4. Please combine all sheets into a single PDF document. Include the Plot Layout, One Line Diagram, Three Line Diagram, and Roof Panel Layout Plan.
5. Please Resubmit
Contact Sean Severson with any questions: sean.severson@tucsonaz.gov
06/18/2025 PDSD Application Completeness Express REVIEW COMPLETED