Permit Number: TC-RES-0525-02422
Parcel: 113052050

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0525-02422
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/16/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/10/2025 Addressing Validation REQUIRES RESUBMIT Linked to TC-RES-0625-02950. Both structures will need to complete Request for Address Change in sub-records on TDC-Online after addressing is completed with Pima County. Resubmit all documents with the correct address/unit so that permit and plan set matches. For questions: Building_Official@tucsonaz.gov
06/03/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0525-02422

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans.

Each dwelling requires a separate permit with an appropriate address. Provide a separate application and submission for the addition to the primary dwelling. The same plan set may be used with the additional submission.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

GENERAL COMMENTS :

1. This submission includes all proposed structures shown on sheet A-1N. Structures on A-1S requires a new submission.

PLANS:

1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions.

PLUMBING PLANS:

1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate water meter size for the additional demand.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
06/16/2025 Site Engineering - Standard REQUIRES RESUBMIT See Addressing comment. Proceed with address correction on both permits, and their affiliated Floodplain Use Permits.
06/06/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0525-02422
3444 N JACKSON AV. – R-2
Attached ADU and Garage and Porch addition to main dwelling (1st Review)

TRANSMITTAL DATE: June 6, 2025

Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments.

This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence (SFR) with an attached accessory dwelling (ADU) is a permitted use in this zone (Table 4.8-1). See Use-Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

1. Clearly demonstrate that the requirements of UDC Article 6.6.3.B.4 are met for the ADU.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
05/07/2025 PDSD Application Completeness Express REVIEW COMPLETED