Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0525-02398
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/09/2025 | Residential Building - Standard | APPROVED | |||
| 09/22/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/22/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Zoning Review Section PROJECT: TC-RES-0525-02398 642 W FLORENCE ST – MH-1 Zoning New Single-Family Residence (3rd Review) TRANSMITTAL DATE: 09/22/2025 This site is located in the MH-1 zone (UDC 4.7.10). A single-family residence is a permitted use in this zone (Table 4.8-2). COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: The site plan should be designed to include the information as noted on the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf . 2. Comment: Label on the site plan the zone (MH-1) and all the adjacent property zones (MH-1). Or show a zoning detail of this properties zone and all adjacent property zones. (As noted on the sample plot plan above) 3. Comment: The west property line utility easement is 7.5’ not 5’. This dimension is found on the subdivision plan here, https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-11073&0 The “proposed residence” obstructs the west utility easement. Utility easements cannot be obstructed. 4. Comment: Dimension the rear alley (20’). This dimension is found on the subdivision plan here, https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-11073&0 5. Comment: Per UDC article 6.4.3, lot coverage shall need to include the area of a lot covered by buildings, storage areas, including dimensioned Vehicular use areas. Do not include porch square footage in the total lot coverage calculations. (As noted on the sample plot plan above). 6. Comment: Provide a measurement scale on each Elevation Sheets (Pages 3 & 4). 7. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide updated site plan in the next submittal. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 08/19/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |