Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0525-02346
Parcel: 136336370

Address:
9485 E MYRA DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.4

Permit Number - TC-RES-0525-02346
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/30/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/30/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0525-02346 – Residential Building – Unpermitted Storage Shed
9485 E Myra Dr Tucson, AZ 85730 (R-1 Zoning)
Building Plan Review – 2nd Review

TRANSMITTAL DATE: July 30, 2025

This site is in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Plan review for the above referenced storage shed has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:
The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
Correct the following plot (site) plan, as noted in the comments below, along with a detailed response letter indicating responses to the review comments.

PLANS:

1. COMMENT: The site plan provided is incomplete. Provide updates to the following:

a) Per https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=29041
the property dimensions should be 76’-0” and 110’-0” respectively. Recalculate Lot Area square footage and update table information on two locations respectively.

b) Add 200 square feet to accessory structures in lot coverage calculations and adjust numbers accordingly.

c) Add a dimension from the south wall of existing garage and storage shed to the south property line.

d) Draw, label, and provide a 20’ street perimeter (front yard setback) graphic off of south property line.

e) Change Wash label in all locations to 16’ Alley.

2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code .

Please contact the zoning reviewer if you have any zoning questions:

Jeffrey W Cassidy
City of Tucson Site Zoning and Planning Reviewer
jeffrey.cassidy@tucsonaz.gov / (520) 837-4916

Additionally, our in-person counter at the Public Works building at 201 N Stone Ave Tucson, AZ 85701 is open and available Monday thru Thursday, 8am-12pm. Ask to speak with me for an in-person consultation to go over my comments if you feel this option will better serve your follow up needs.

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
07/02/2025 PDSD Application Completeness Express REVIEW COMPLETED