Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0524-03257
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/27/2024 | Site Engineering | NOT REQUIRED | |||
| 06/27/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/13/2024 | Residential Building | REQUIRES RESUBMIT | The roof structure may not extend to a point closer than 3 feet from the adjoining (neighboring) property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2). | ||
| 06/24/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Review Section PROJECT: TC-RES-0524-03257 843 W CALLE CASTILE TUCSON, AZ 85756 Porch and Carport (1st Review) TRANSMITTAL DATE: 6/24/2024 DUE DATE: 6/30/2024 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Please label adjacent property zoning classifications as noted on the sample site plan. 3. Comment: The existing storage is listed as 790 square feet on your plans. Please clarify as your existing storage shed footprint is listed at 90 square feet. 4. Comment: Please dimension both the existing back porch and the existing storage shed as it appears the square footage provided on your plans is not correct. 5. Comment: Please update the listed setbacks on the site plan to East and West side instead of rear. Also, please update the proposed attached porch to include carport. 6. Comment: Please dimension the street center line to edge of pavement and then from edge of pavement to the property line. 7. Comment: Label and dimension the rear alley as 20’ wide. 7. Comment: Please revise and delineate the driveway to include the proposed vehicular use access area on the West side of the property. Currently, the plans only depict a driveway going to one parking spot. Also, please update the driveway calculations to include the new area. 8. Comment: A Design Development Option (DDO) application review and approval will be required since proposed porch/carport will require a reduced setback from both the West and the North property lines. The West building setback is the greater of 6’ or 2/3 the height of the structure from design grade. Based on the plans at a proposed 10’ 6” height, the minimum setback would be 7’. The North setback is 20’ and you are allowed a 2’ overhang however your proposed plans have a 3’ overhang. Here is a link to the DDO application: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. 9. Comment: Please refer to the building code reviewers’ comments relating to the fire code requirements along the West property line. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov (520) 837-4977. |
||
| 05/30/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |