Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0524-03257
Parcel: 138041080

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.3

Permit Number - TC-RES-0524-03257
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2024 Residential Building APPROVED
09/30/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/30/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Review Section

PROJECT: TC-RES-0524-03257
843 W CALLE CASTILE TUCSON, AZ 85756
Porch and Carport (3rd Review)

TRANSMITTAL DATE: 9/30/2024

DUE DATE: 9/30/2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Comment: Zoning acknowledges that a neighbor waiver has been included with this submittal however the waiver is missing key information about the distance from the property line to the proposed carport/porch addition.

2. Comment: Your included narrative states a DDO is not required since the proposed west structure has been detached from the main residence. Please clearly demonstrate on your plans that the proposed west porch is detached.

A. Per UDC 6.6.3.C, detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for shade structures or carports not over 400 square feet in floor area.

B. Per UDC 6.6.3.E, the total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement.

A variance will be required for any detached accessory structure that exceeds the maximum allowance per 6.6.3.C & E.

3. Comment: Previous comment not addressed: Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. Perimeter yard setbacks for porch/carport type structures are based on a measurement from design grade to the highest point of the wall adjacent to the property line. In this case it would be the tallest post supporting the carport along the west property line. There is no height dimension on the tallest post, 2nd post from the northern most post supporting the carport roof.

4. Comment: A Design Development Option (DDO) must be submitted and approved to reduce the required setback to the west property line if the proposed porch/carport is attached to the principal structure. The DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

5. Comment: Additional comments may be forthcoming based on corrected plans and responses to zoning comments.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov (520) 837-4977.
08/30/2024 PDSD Application Completeness Express REVIEW COMPLETED