05/30/2024 | PDSD Application Completeness | REQUIRES RESUBMIT | Pleas upload a basement floor plan that shows the electrical being removed and they would need to show crawl space venting. Show under-floor space ventilation openings with not less than 1 SF for each 150 SF of under-floor area, R408.2. Show the location of a minimum 18”x 24” access to under floor space that exceeds 30SF, R408.4. If you have any further questions or concerns you can reach me at building_official@tucsonaz.gov. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |