Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.4
Permit Number - TC-RES-0524-03230
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/22/2024 | Residential Building | NOT REQUIRED | See Site Zoning comment. | ||
| 11/26/2024 | Site Engineering | NOT REQUIRED | |||
| 10/30/2024 | Site Landscape | NOT REQUIRED | |||
| 11/26/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/25/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Planner, Zoning Review Section PROJECT: TC-RES-0524-03230 9312 E BARBARA JEAN PL TUCSON, AZ 85710 – R-1 Zoning Shed (1st Review) TRANSMITTAL DATE: 11/25/2024 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Provide a residential plot plan that meets the requirements and is designed to include All the information as noted on the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. 2. Comment: Clarify, is there any utilities that are a part of the shed? 3. Comment: All structures must meet the minimum building setback, the greater of 6’ or 2/3 the height of structure wall facing the property line. The proposed structure is depicted 4’ from the east property line. The shed can be relocated away from the property line to meet the 6’ minimum or a waiver for the proposed setback must be obtained to allow the shed to be built / placed as depicted on the plan. The following verbiage can be used for the setback waiver and must be Added to the site plan. *This neighbor waiver is to be added to the site plan* Example of an adjacent owner’s setback waiver for detached accessory structures. The adjacent owner’s waiver statement must be Added to the site plan. The following statement can be used. My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are unable to secure a waiver a Design Development Option (DDO) application must be submitted for review and approval. 4. Comment: Draw, label, and dimension the 7.5’ easement on the south of the property. Lot 53 dimensions can be found in Recorded Subdivision Plat Map Book 22, Page 8. Here is a link to those dimensions: https://maps-and-records.tucsonaz.gov/subdivisions/details/2612 5. Comment: List the height of the shed on the site plan for all elevations of the proposed structure. The height of the proposed shed is measured from design grade (the ground) to the top of the wall. 6. Comment: Aerial views show a shade structure appear on the south side of the property sometime between 2022 and 2023. No permit history can be found for this structure. All structures shall be drawn, labeled, and dimensioned on the site plan and included in the lot coverage calculations. If this structure is greater than 200 square feet it will require a building permit and may be included with this current permit review. If this structure has been removed, then indicate it is no longer there. Additional comments may be forthcoming regarding this unpermitted structure based on the information provided. 7. Comment: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. The following comments are related to the DDO IF necessary. 1. DDO Comment: The perimeter yard setback along the east property line does not comply with the minimum setback. Per UDC 6.3-2.A, the minimum perimeter yard setback is the greater of 6’-0” or 2/3 (H) height of the exterior wall. The structure encroaches into the required perimeter yard at 4’ and will require the approval of a Design Development Option (DDO) before zoning can approve this permit. The below paperwork can be filled out and submitted with the next submission. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf For more information about the DDO process contact Mark Castro at mark.castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide a Site plan that meets the requirements in the next submittal. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 10/28/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |