Permit Number: TC-RES-0524-03192
Parcel: 136072240

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0524-03192
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2024 Site Engineering NOT REQUIRED
06/26/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/13/2024 Residential Building REQUIRES RESUBMIT TC-RES-0524-03192
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections.

Provide a response letter on separate file with submitting the updated construction plan set.

Remove the “existing” label from all proposed additions and alterations. Label as “built w/o permit”.

Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Provide a site plan showing the location of the electrical service panel, R106.1.

FLOOR PLAN:

1. Provide construction plans for the closet accessed from the proposed family room, R310.

STRUCTURAL PLANS:

1. Provide a complete plan set showing materials and fastener sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1.

SECTIONS – DETAILS - NOTES:

1. Provide a complete list of keynotes (1-18) on sheet 5, R106.1.
2. Provide the foundation section detail indicated to be on drawing A1.3, R106.1. Also, provide the foundation detail indicated at elevation 1 on sheet 5 & 6.
3. Clarify keynote #15 on sheet 3.

PLUMBING PLANS:

1. Show any proposed changes, R301.1.

MECHANICAL PLANS:

1. Show heating/cooling facilities in all habitable rooms, R303.9.

ELECTRICAL PLANS:

1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12.
2. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2.
3. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3.
4. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2.
5. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3.
6. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
06/18/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0524-03192
1400 South Rocky Mountain Drive – R-1
Residential remodel and additions (CE-VIO0424-01247) (1st Review)

TRANSMITTAL DATE: June 18, 2024

The site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9.

1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. At a minimum, the submitted site plan shall include the following additional information:
a. Show the location of all existing and new structures and their uses;
b. Provide setbacks measured from all existing and proposed structures to all property lines; and
c. Show dimensions from the centerlines of Brown Avenue and Rocky Mountain Drive to the curb locations, and dimensions from the curb locations to the street property lines. Refer to sheets two, three, and five of paving plan I-70-032 for specifics: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-70-032.

2. As the existing carport was previously enclosed, show the required motor vehicle parking spaces fully dimensioned on the site plan.

3. Label each room on the floor plan to determine whether use-specific standard 4.9.7.B.7 applies to the proposal.

For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.

Per UDC 11.4.3, the term bedroom includes all of the following: 1) Any room that is designated as a bedroom; 2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement.

4. Per UDC 6.4.5.C.1.b, where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line.

As the existing storage shed and recently added porch do not meet the above setback requirement, a Design Development Option (DDO) is required to reduce the side street setback to less than ten feet.

The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Mark.Castro@tucsonaz.gov or Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process.

5. Perimeter yard setbacks are based on a measurement from the design grade elevation to the highest point of an exterior building wall (see UDC 6.4.5.B and Figure 6.4.5-A). Per UDC Table 6.3-2.A, when a residential is adjacent to a residential zone, the required side and rear perimeter yard setbacks are six feet or 2/3 the height of the exterior building wall, whichever is greater.

Based on a wall height under 9’-0”, the required side and rear setbacks are 6’-0” as measured from the south and west lot lines to the proposed shed. Indicate the proposed setbacks on the site plan.

The waivers shall be signed by the owners of 1401 South Brown Avenue, 1415 South Brown Avenue, and 1410 South Rocky Mountain Drive. The waivers shall be pasted directly on the site plan with the following language:

My name is _______ and I am the owner of property located at _______. I have reviewed the site plan and I have no objection to the structure being constructed __ feet from the property line as depicted on the site plan.

Signature: _______

Date: _______

If all required waivers cannot be obtained, a DDO may be processed to reduce the setbacks to as little as one foot. A Board of Adjustment variance is required to be granted to allow a zero-foot setback if all waivers cannot be obtained.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
05/28/2024 PDSD Application Completeness Express REVIEW COMPLETED