Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0524-03192
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/26/2024 | Residential Building | APPROVED | |||
| 01/13/2025 | Site Engineering | NOT REQUIRED | |||
| 01/14/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/14/2025 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0524-03192 1400 South Rocky Mountain Drive – R-1 Residential remodel and additions (CE-VIO0424-01247) (2nd Review) TRANSMITTAL DATE: January 14, 2025 The site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9. 1. This comment was not addressed. The overall floor plan does not show labels for all rooms. It appears that there are at least 5 bedroom if not 6. Clarify what size the opening is between the “FAMILY ROOM” and the existing dwelling and if there is a door in this location. If this opening is a minimum 5’ wide without a door the family room would not be considered a bedroom. If there is a door at this location the family room is considered a bedroom. If the opening is less than 5’-0 wide with or without a door the family room is considered a bedroom. If the family room is considered a bedroom there are 6 bedroom on site and 4 vehicle parking spaces are required. If the family room does not count as a bedroom than there are 5 bedrooms on site and 3 vehicle parking spaces are required. The required vehicle parking spaces shall be located in the side or rear yard. Clearly show the required parking spaces on the plan along with access to them fully dimensioned. Also clearly demonstrate that the required dustproofing is provided. Label each room on the floor plan to determine whether use-specific standard 4.9.7.B.7 applies to the proposal. For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family dwellings in the R-1 zone with five or more bedrooms, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. Per UDC 11.4.3, the term bedroom includes all of the following: 1) Any room that is designated as a bedroom; 2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement. 2. The 2 parking spaces shown in the front driveway may not count towards the required vehicle parking spaces. 3. This comment was not addressed. Until the required DDO is submitted and approved Zoning cannot approve this plan. Per UDC 6.4.5.C.1.b, where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line. As the existing storage shed and recently added porch do not meet the above setback requirement, a Design Development Option (DDO) is required to reduce the side street setback to less than ten feet. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Mark.Castro@tucsonaz.gov or Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process. 4. The rear and south perimeter yard setbacks shown are not correct and should be the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 5. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 12/14/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |