Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0524-03189
Parcel: 136390410

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.3

Permit Number - TC-RES-0524-03189
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2024 Site Engineering NOT REQUIRED
08/22/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
07/29/2024 Residential Building REQUIRES RESUBMIT TC-RES-0524-03189
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a response letter on separate file when submitting the updated construction plan set.

Structures built without a permit may require alteration for building code compliance.

Provide a clear and concise construction plan set. See the Porch Sample for plan requirements. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Indicate the location and size of the proposed structure requiring a permit, R106.1.1.

STRUCTURAL PLANS:

1. Show the location of each support footing, R106.1.1.
2. Specify method of transferring lateral forces from the roof diaphragm to the supporting structural elements (without fascia end-grain nailing), R801.2.
3. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1.
4. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1.

SECTIONS - DETAILS:

1 Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1.
2 Provide structural roof sheathing and fastening in compliance with Table R602.3 (1).
3 Notate the spacing and size of ledger anchorage if used, R606.11.
4 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

ELECTRICAL PLANS:

1. Show any electrical alterations.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
08/20/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0524-03189 - CE-VIO0524-01730
4784 S PRUDENCE RD - R-3
Porch Built Without Permit (2nd Review)

TRANSMITTAL DATE: August 20, 2024

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-3 zone (UDC 4.7.12). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

1. Clearly show the porch on the plan along with the size, height and perimeter yard setbacks to the applicable property lines.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/23/2024 PDSD Application Completeness REVIEW COMPLETED